Case IH 3 – TMF: Hitch Raise Solenoid High Side Driver shorted to 12 volts.
Descrizione del problema
The control module has detected that the high-side driver circuit (the circuit responsible for supplying power to the hitch raise solenoid) is receiving or bypassing directly to a 12-volt power source inappropriately. This condition prevents the controller from properly regulating the rear (or front) hitch raise function.
Si applica a queste macchine
7 macchine- Magnum
- Magnum Series
- MX Magnum
- TG Series
- Puma Series
- Steiger Series
- Farmall Series
Verifica la causa
Visually inspect the wiring harness running from the TMF controller to the hitch raise solenoid for melted insulation, pinched wires, or areas rubbing against the chassis.
Disconnect the hitch raise solenoid plug and the TMF controller connectors to inspect for water ingress, corrosion, or bent pins that could bridge 12V power to the driver pin.
With the key ON (engine off) and the solenoid disconnected, probe the high-side driver wire at the solenoid connector with a multimeter. If 12 volts is present when not commanded to raise, there is a short to power in the harness.
Measure the resistance of the hitch raise solenoid coil to determine if the coil is internally shorted.
Passaggi di riparazione
Disconnect Power
Turn off the ignition and disconnect the tractor's battery to prevent further electrical damage or accidental shorting during repair.
Isolate the Short
If the multimeter test revealed 12V on the harness side, trace the wiring harness back to the TMF controller. Repair or splice the damaged section of the wire where it has shorted to a power source.
Replace the Solenoid
If the wiring harness tests perfectly fine, the fault is likely an internal short within the hitch raise solenoid coil. Relieve hydraulic system pressure, unplug the electrical connector from the hitch raise solenoid, unthread the retaining nut and slide the old solenoid coil off the valve stem (or replace the entire valve assembly depending on the specific model's configuration). Install the new solenoid and tighten to OEM torque specs.
Reassemble and Clear Codes
Reconnect the battery. Turn the key on and use the tractor's diagnostic display (or a CAN-bus scanner) to clear the inactive TMF 3 fault code.
Recalibrate
Run the hitch calibration procedure via the armrest display to ensure the TMF controller learns the threshold of the new raise valve solenoid.
Ricambi che potrebbero servirti
(6)Hitch Solenoid Valve
47379783Magnum / Steiger / Puma
Hitch Solenoid Coil
87608473Solenoid Valve Assembly
320691A1Older Magnum 7110-8950 series. Supersedes older part # 1272538C1.
Solenoid Valve Assembly (Older)
1272538C1Superseded by 320691A1
TMF Controller
87393065If the internal driver is permanently burned out
TMF Controller
87617964If the internal driver is permanently burned out
Ricevi assistenza per risolvere questo errore richiedendo un preventivo